Product Details:

  • Installation Type Stand-alone or Integrated Pipe Network
  • Product Type Gas Suppression System
  • Fire Class Class A, B, C (fires involving solids, liquids, and gases)
  • Features Non-conductive, residue-free, environment-friendly, rapid action
  • Energy Efficiency Rating Highly efficient, minimal energy consumption during standby
  • Technology Clean Agent Gas Suppression; Total Flooding System
  • Control Type Automatic & Manual Release
X

Gas Suppression System Product Specifications

  • 0C to 49C
  • Stand-alone or Integrated Pipe Network
  • Gas Suppression System
  • Class A, B, C (fires involving solids, liquids, and gases)
  • Corrosion-resistant powder-coated finish
  • Cylindrical
  • Up to 300 m2 (varies per design and agent)
  • Automatic Modular Gas Suppression
  • Fire Fighting
  • 180 mm (Cylinder) approx.
  • Super-pressurized to 25-42 bars
  • Depends on agent type and nozzle size; typically 2-10 kg/sec
  • Highly efficient, minimal energy consumption during standby
  • Non-conductive, residue-free, environment-friendly, rapid action
  • 25 Bar to 42 Bar (360-610 psi)
  • 5 kg to 100 kg (per cylinder)
  • Automatic & Manual Release
  • Server Rooms, Data Centers, Electrical Panels, Archives, Telecom Facilities
  • Red
  • Clean Agent Gas Suppression; Total Flooding System
  • Wired system integration with Fire Alarm panels
  • 24V DC (control panel operated)
  • Floor-mounted or Wall-mounted
  • Pressure gauge, safety valve, discharge hose, nozzle, mounting brackets
  • UL listed, FM approved, ISO certified
  • FM-200 (HFC-227ea), NOVEC 1230, or CO2 options available
  • Electrically actuated solenoid valve
  • Seamless steel
  • Red
  • Smoke/heat detection using spot or linear detectors
  • Multi-directional with flow restrictors

Gas Suppression System Trade Information

  • All India

Product Description

We introduce ourselves as a noteworthy organization engaged in offering Gas Suppression System that controls and extinguishes fires without human intervention. This system is easy to refill with extinguishing agents, fitted with nozzle & has excellent suppressing capacity. Our Gas Suppression System is very economical and offered within the specified time limits. Automatic in nature, highly flexible and compactly designed are features of given product. In addition to this, our clients can buy this Gas Suppression System from us at the most leading rates.

Fire Protection Gas Suppression System or simply called as Automatic Fire Suppression System (or Gas Suppression System), is relatively a new technology in India. Unlike conventional system that use water, in Gas Based Fire Suppression System; water is never used and yet the fire is extinguished. Here Gas is used to extinguish the fire. Hence it is a Gas Based system. The fire gets extinguished, within a minute of activation and everything is automatic.

Is it always necessary to provide Fire Protection with Gas Suppression System ? Or Why go for a Gas Suppression System?

Absolutely not. In certain areas like Server Systems, Art Galleries or near delicate machinery, water can cause more and permanent damage than the fire. In the Server Room, the data in the server is more costly than the server itself. If the art piece or data, gets damaged or lost; it would result in an immeasurable loss.

How do Gas Suppression System Function ?

Gas Suppression Systems are generally used in concealed rooms. The principle used by Gas Suppression System is by breaking the Fire Triangle, the fire ceases to exist. In the room, protected by Gas Suppression System, there are various detectors placed at various locations. Each detector constantly monitors the room for signs of fire. As soon as fire is detected, an alarm is sounded, to the personnel to evacuate the entire room. Then, the a gas like, Novec, Clean Agent or Co2 is released in the enclosed room. Thus, the oxygen in the room is rapidly reduced, to a level where fire cannot exist. However, living organisms remain unharmed, because of the gas. Because of such a system, all the delicate or critical items remain untouched and unharmed by fire or water.

There are generally, two principles used in Gas Suppression Systems :

1) The Total Flooding Principle : The Gas Suppression System is used in an enclosed room or isolated location.

2) The Local Application Principle : The Gas Suppression System is directly applied to the fire, immediately on the fire affected area. There are no physical barriers present, as in the case of the total flooding principle.

What are the advantages of Gas Suppression System?

  • The main advantage of Gas Suppression System, system is that it is very quick.
  • The gas used in Gas Suppression System, does not have any smell or colour. It is also friendly to nature. Gas Suppression System also have very easy maintenance and occupy lesser space.
  • It does not have any kind of flavour.

What are the dis-advantages of Gas Suppression System?

  • There are but, a few disadvantages of such a system. Firstly it can only be used in enclosed spaces and secondly, that is relatively costly.
  • There are various Clean Agent Fire Suppression Systems or Gas Suppression systems used in the market
  • FM 200 Clean Agent Systems
  • Novec 1230 Clean Agent Systems or Novec Fire Protection System
  • FE-13 Clean Agent Systems
  • Carbon Dioxide Co2 Clean Agent Systems or Co2 Total Flooding System


Engineered for Sensitive Environments

Designed for use in areas where electronics or valuable assets are present, our gas suppression systems deploy clean agents that leave no residue and do not conduct electricity. Their rapid action and minimal impact make them especially suitable for places like server rooms, archives, and sensitive electrical installations.


Versatile Design and Compatibility

The system's cylindrical, powder-coated steel cylinders can be floor or wall mounted and accommodate capacities from 5 kg to 100 kg. Whether you require a stand-alone installation or integration with a larger pipe network, our system adapts seamlessly and covers up to 300 m2 per design and agent specification.


Advanced Detection and Activation

Equipped with smoke and heat detectors, the system offers early warning and quick response. Automated activation via solenoid valves or manual release ensures effective fire suppression. It operates at 24V DC, integrating easily into standard fire alarm panels while maintaining high energy efficiency.

FAQ's of Gas Suppression System:


Q: How does the gas suppression system activate in case of fire?

A: The system uses smoke or heat detection through reliable spot or linear detectors. Upon detecting a fire, it triggers the electrically actuated solenoid valve, releasing the clean agent automatically. Manual activation is also available via the control panel if required.

Q: What types of fires can this suppression system address?

A: Our gas suppression system is suitable for Class A (solids), Class B (liquids), and Class C (gases) fires. Its clean agent technology is particularly effective in environments with sensitive electronics or valuable records.

Q: Where is the ideal application for this system?

A: This system is best suited for server rooms, data centers, telecom facilities, electrical panels, and secured archives-environments where conventional suppression may cause collateral damage.

Q: What are the key benefits of using FM-200, NOVEC 1230, or CO2 agents?

A: These agents are non-conductive, act rapidly, leave no residue, and are environmentally friendly. Their use prevents equipment damage and reduces downtime after a fire event.

Q: When should I opt for a stand-alone versus an integrated pipe network installation?

A: A stand-alone setup is ideal for single, protected enclosures or smaller rooms. For larger areas or multiple zones, integration with an existing pipe network enables broader coverage and centralized control.

Q: How is the system maintained for ongoing safety?

A: Regular inspections of pressure gauges, safety valves, detectors, and system electronics are recommended. Compliance with UL, FM, and ISO guidelines ensures the system remains optimally functional.

Q: What is the typical process for deploying this gas suppression system?

A: After assessing your site requirements, the suitable agent and capacity are selected. The system is then installed with seamless steel cylinders, connected to fire detectors and control panels. Routine commissioning and periodic maintenance guarantee its readiness in case of fire.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Fixed Fire Protection & Detection System' category